Tesla Industries Inc.
109 CenterPoint Blvd.
New Castle, DE 19720
(302)324-8910 Phone
(302) 324-8912 Fax
www.TESLAind.com
TI4676
Vista de página 0
1 2 3 4 5 6 ... 36 37

Resumo do Conteúdo

Página 1 - Tesla Industries Inc

!"#$%&'%()$&*+",'%()$)-&./Tesla Industries Inc.109 CenterPoint Blvd.New Castle, DE 19720(302)324-8910 Phone(302) 324-8

Página 2

2-47) Replace thewhite clip back intothe fuse clip. Takecare not to damagethe tabs.8) Completely insertwhite clip in to fuseclip (GENTLY) untilit snap

Página 3 - TABLE OF CONTENTS

CHAPTER 3OPERATING LIMITS AND RESTRICTIONSSECTION I. GENERAL3-1. PURPOSEChapter 3 includes all important operating limits and restrictions thatmust b

Página 4 - CHAPTER 1

3-4. 120-240 50/60 Hz VAC CHARGER AND AC TO DC CONVERTER LIMITSThe unit is designed with a single point AC receptacle for externalpower to operate b

Página 5

AC Line Cords North American Old British U.K Cont. Europe (more examples in appendix or call factory for information)CAUTION*8

Página 6

3-8. CONTINUOUS OUTPUT RATE, 28.5 VDC CONSTANT OUTPUT35 Amps at 1 hour (with AC power connected)NOTEIf current demand exceeds 12 amps, converter out

Página 7 - CHAPTER 2

CAUTIONUnit may be damaged if operated when unit’s cold or heat soaked tem-perature exceed the specified limit. If unit is operated when cold orheat

Página 8 - TI4676:

WARNING********SHOCK HAZARD POTENTIAL*********Severe injury, or Death, from electrical shock is possible when person-nel and/or TI4676 are wet during

Página 9 - !"#

CAUTIONUnit damage may occur if inlet and outlet vent ports are obstructedand/or cooling airflow is restricted. Back Vent Side Ve

Página 10 - Fuse Setting Procedures

CHAPTER 4OPERATING AND INSTALLATION PROCEDURESSECTION I. UNIT INSTALLATION4-1. INSTALLATION1. Remove original aircraft battery and dispose of properl

Página 11 - CHAPTER 3

SECTION II. OPERATING PROCEDURES (cont.)4-5. OPERATING PROCEDURESThis section deals with normal procedures, and includes all steps nec-essary to ensu

Página 12 - 32: (5 6285&(

WARNING*******SHOCK HAZARD POTENTIAL*******IMPROPER USE/FAILURE TO FOLLOW INSTRUCTIONS IN OPERATORS MANUAL CAN RE-SULT IN UNIT FAILURE AND/OR POSSIBLE

Página 13

CAUTIONREMEMBER, when the AC line cord is plugged in, the unit must be placedin a position to allow the cooling fan to operate properly!Unit may over

Página 14 - (C0NTINUED ON NEXT PAGE)

CAUTIONUnit may overheat if cooling fan fails.Do not operate if cooling fan fails.2. CHECK FOR FULL CHARGE INDICATION - After 1 HR 15 minutes, LEDcha

Página 15

SECTION III.FUNCTIONAL CHECK PROCEDURES AND TROUBLE SHOOTING4-8. FUNCTIONAL CHECK PROCEDURESThis section deals with normal functional check procedure

Página 16

7. CHECK DC VOLTAGE READING AT DC RECEPTACLE TERMINALS. Ensure powercells are fully charged (see step 6.)28.5 (±0.57 VDC) with power cells at full s

Página 17

CHAPTER 5PERFORMANCE DATASECTION 1. INTRODUCTION5-1. PURPOSEThis chapter provides performance data for the TI4676. Continual refer-ence to this info

Página 18 - CHAPTER 4

SECTION IIDATA CRITERIA5-3 DATA BASISThe type of data used is indicated at the bottom of each performancechart under DATA BASIS. The applicable repor

Página 20

FIGURE 5-25-4TI4676MPU-24 OUTPUT VOLTAGEOUTPUT VOLTAGEMINUTES23 AMP CONSTANT CURRENT LOAD24201612840010 2030405060

Página 21

MAXIMUM OUTPUT CURRENTAMPSCalculation based on actual test data at Pratt-Whitmey on 30 March 1992SECONDS1500135012001050900750600450150300005101520253

Página 22

CHAPTER 6CARE AND MAINTENANCESECTION I. UNIT CARE6-1. GENERAL Although the TI4676 has been ruggedized and made weather resistantwithin the scope of

Página 23

TABLE OF CONTENTSTITLE PageCHAPTER 1 INTRODUCTION 1-1CHAPTER 2 UNIT DESCRIPTION AND OPERATION

Página 24 - CHAPTER 5

Chapter 7Push To Test ModificationGeneral Information And Operation7-1. GeneralTHIS MODIFICATION HAS BECOME STANDARD EQUIPMENT FOR EACH OF OURUNITS.

Página 25

PARAGRAPH INDEX120-240 50/60 Hz VAC Charger and AC to DC Converter Limits, 3-4Abbreviations, 1-5AC Power Cord Limits, 3-5After Use, 6-2Appendix A

Página 26 - FIGURE 5-1

PARAGRAPH INDEXIndex, 1-4Installation, 4-1Maintenance of Unit, 6-3Maximum Output Current, Figure 5-3One (1) Hour Rate, 24 VDC Constant Output, 3-6

Página 27 - OUTPUT VOLTAGE

APPENDIX AOPTIONAL LINE CORDS FOR WORLDWIDE OPERATIONSCOUNTRY VOLTS HZ TESLA PART #Afganistan 220 50 TI25000-004 Old British Lin

Página 28 - FIGURE 5-3

APPENDIX A (Cont.)OPTIONAL LINE CORDS FOR WORLDWIDE OPERATIONSCOUNTRY VOLTS HZ TESLA PART #Ecuador 120 60 TI25000-001 North Amer

Página 29 - CHAPTER 6

APPENDIX A (Cont.)OPTIONAL LINE CORDS FOR WORLDWIDE OPERATIONSCOUNTRY VOLTS HZ TESLA PART #Laos 220 50 TI25000-001 North America

Página 30 - Chapter 7

APPENDIX A (Cont.)OPTIONAL LINE CORDS FOR WORLDWIDE OPERATIONSCOUNTRY VOLTS HZ TESLA PART #Romania 220 50 TI25000-003 Cont. Euro

Página 31

A-5APPENDIX A (Cont.)UNIVERSAL LINE CORD KIT FOR WORLDWIDE OPERATIONSNOTE: TESLA UNIVERSAL AC LINE CORD KIT, P/N: TI25000-U00, IS FORUNITS ORIGINALLY

Página 32

CHAPTER 1INTRODUCTION1-1. GENERALThese instructions are for use by the owner/operator. They apply tohandling and operation of the TI4676 Micro Power

Página 33 - APPENDIX A

1-4. INDEXThe index lists, in alphabetical order, every titled paragraph and fig-ure contained in this manual.1-5. ABBREVIATIONS AND SYMBOLSAbbrevia

Página 34 - APPENDIX A (Cont.)

1-6. FORMS AND RECORDSNONE REQUIRED.1-7. USE OF WORDS SHALL, SHOULD, AND MAY.Within this technical manual the word “shall” is used to indicate amand

Página 35

CHAPTER 2UNIT DESCRIPTION AND OPERATIONSECTION I. UNIT2-1. GENERALThe TI4676 (Figure 2-1) is a compact, portable and highly versatile 24/28.5 VDC ele

Página 36

WARNING Check fuse holder window to ensure the fuse setting reads either120 or 240 prior to connecting recharge cord to AC power source. Fusesetting

Página 37

!"#$%&'!"#